Halo DB-30 : Accessories
UV / Visible Double Beam Spectrophotometer



View larger Image

Rectangular Long-Path Cuvette Holder


Designed for low concentration or low absorbance samples
> Accommodates 2 x long–path cuvettes (sample and reference sides)
> Accepts cuvettes with 6 optical path lengths of: 10,20, 30, 40, 50 & 100 mm

Cylindrical Long-Path Cuvette Holder:


Designed for low concentration or low absorbance samples using a cylindrical cuvette

> Accommodates 2 x long–path cylindrical cuvettes (sample and reference sides)

Thermostatic Cuvette Holder


Designed for applications requiring incubation and/or maintenance of a sample at a constant temperature

> External water circulation maintains temperature stability
> Operating temperature range: Room Temperature to +40°C
> Temperature stability: ±0.3°C
> Complete with tubing for quick connection to water source (such as circulating water bath)

5-Cuvette Holder / Changer


Designed for mounting up to 5 standard 10mm cuvettes on the sample beam side.

> Total capacity: 5 cuvettes on sample beam side + 1 cuvette on reference beam side
> Turret design cuvette holder for efficient changeover
> Manual change of cuvettes by turning front mounted knob - no temperature control

6-Cuvette Holder / Changer (with electronic temperature control):


Designed for mounting up to 6 standard 10mm cuvettes with temperature control and stirring

> Total capacity: 6 cuvettes on sample beam side + 1 cuvette on reference side
> Electronic change over – change cuvettes automatically at defined time intervals
> Electronic thermostat – set temperature between +20°C to +40°C
> Includes magnetic stirrer (and fleas)
> Requires water circulated cooling (tubing included)

6-Cuvette Holder / Changer (without electronic temperature control):


Designed for mounting up to 6 standard 10mm cuvettes without temperature control and stirring

> Total capacity: 6 cuvettes on sample beam side + 1 cuvette on reference side
> Electronic change over – change cuvettes automatically at defined time intervals

Micro-cuvette Holder


Designed for measuring micro-volumes with 50µl micro-cuvette

> Wavelength range: 220 to 880nm
> Noise level: ~0.001Abs(with 50µl volumes)

Micro-cuvettes


Suitable for use in the micro-cuvette holder

> Made from quartz
> Available size: 50µl

Auto Sample Sipper (without temperature control)


Designed for the rapid measurement of multiple or large amounts of sample without the requirement for manual washing or changing of cuvettes. The sample is sipped from an external tube directly into the sipper’s integrated cuvette and automatically measured. The sample can also be recovered post-measurement.

Two models are available with and without electronic temperature control, the former maintains the flow cuvette section at a constant temperature.

> Minimum sample volume: 0.7ml
> Wavelength range: 190nm – 900nm
> Carryover: ≤1%
> Sipper cuvette capacity: ~50µl
> Optical path length: 10mm

Auto Sample Sipper (with temperature control)


The same features as the Auto sipper with the added convenience of electronic temperature control to maintain the flow cuvette section at a constant temperature.

> Temperature control range: +20°C to +40°C
> Requires water circulated cooling (tubing included)

Micro Flow Cuvette Holder


Designed for the continuous measurement of trace samples. The sample can be injected directly into the flow cuvette with a syringe or other injection device.

> Flow cuvette capacity: 70µl
> Pressure tolerance: Max. 0.1Mpa
> Optical path length: 10mm
> Teflon tubing provided

Glass Sample Holder


Designed for measuring the transmittance /absorbance of glass samples or filters.

> Glass sample thickness: 0.5mm to 5mm
> Glass sample dimensions: Min. 12x25mm to Max. 55x100mm

Film Sample Holder


Designed for measuring the transmittance /absorbance of thin film-like samples.

> Film sample dimensions: 25mm (W). 30 to 50mm (H)
> Beam aperture: 10mm(W) x 20mm (H)

Download the Halo Brochure >>